Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38175170

RESUMO

Silicon dioxide (SiO2), in its amorphous form, is an approved direct food additive in the United States and has been used as an anticaking agent in powdered food products and as a stabilizer in the production of beer. While SiO2 has been used in food for many years, there is limited information regarding its particle size and size distribution. In recent years, the use of SiO2 food additive has raised attention because of the possible presence of nanoparticles. Characterization of SiO2 food additive and understanding their physicochemical properties utilizing modern analytical tools are important in the safety evaluation of this additive. Herein, we present analytical techniques to characterize some SiO2 food additives, which were obtained directly from manufacturers and distributors. Characterization of these additives was performed using dynamic light scattering (DLS), transmission electron microscopy (TEM), field emission scanning electron microscopy (FE-SEM), and single-particle inductively coupled plasma mass spectrometry (spICP-MS) after the food additive materials underwent different experimental conditions. The data obtained from DLS, spICP-MS, and electron microscopy confirmed the presence of nanosized (1-100 nm) primary particles, as well as aggregates and agglomerates of aggregates with sizes greater than 100 nm. SEM images demonstrated that most of the SiO2 food additives procured from different distributors showed similar morphology. The results provide a foundation for evaluating the nanomaterial content of regulated food additives and will help the FDA address current knowledge gaps in analyzing nanosized particles in commercial food additives.


Assuntos
Nanopartículas , Nanoestruturas , Dióxido de Silício/química , Aditivos Alimentares/análise , Nanopartículas/química , Análise Espectral , Tamanho da Partícula
2.
Nanoscale ; 14(12): 4690-4704, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35262538

RESUMO

We describe the outcome of a large international interlaboratory study of the measurement of particle number concentration of colloidal nanoparticles, project 10 of the technical working area 34, "Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS). A total of 50 laboratories delivered results for the number concentration of 30 nm gold colloidal nanoparticles measured using particle tracking analysis (PTA), single particle inductively coupled plasma mass spectrometry (spICP-MS), ultraviolet-visible (UV-Vis) light spectroscopy, centrifugal liquid sedimentation (CLS) and small angle X-ray scattering (SAXS). The study provides quantitative data to evaluate the repeatability of these methods and their reproducibility in the measurement of number concentration of model nanoparticle systems following a common measurement protocol. We find that the population-averaging methods of SAXS, CLS and UV-Vis have high measurement repeatability and reproducibility, with between-labs variability of 2.6%, 11% and 1.4% respectively. However, results may be significantly biased for reasons including inaccurate material properties whose values are used to compute the number concentration. Particle-counting method results are less reproducibile than population-averaging methods, with measured between-labs variability of 68% and 46% for PTA and spICP-MS respectively. This study provides the stakeholder community with important comparative data to underpin measurement reproducibility and method validation for number concentration of nanoparticles.

3.
Anal Chem ; 94(7): 3091-3102, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35144383

RESUMO

Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that is capable of simultaneous measurement of the size and number concentration of metal-containing nanoparticles (NPs) at environmentally relevant levels. Although spICP-MS is widely applied to different fields, challenges remain in obtaining accurate and consistent particle number concentration (PNC) measurements. This paper presents, for the first time, a rigorous assessment of spICP-MS capabilities for measuring the PNC of gold NP (AuNP) suspensions of different sizes and coatings. The calibration of spICP-MS was accomplished with the National Institute of Standards and Technology (NIST) AuNP reference material (RM) 8013. The comparability of both spICP-MS direct and derived determination of PNC and reference PNC derived based on the mean particle size or the particle size distribution obtained by different reference sizing techniques was first assessed for NIST AuNP RM 8012, nominal diameter 30 nm. To enable a proper assessment of the accuracy of the spICP-MS results, a comprehensive estimation of the expanded uncertainty for PNC determination was carried out. Regardless of NP size or coating, a good agreement (90-110%) between spICP-MS direct determination of PNC and reported PNCs was obtained for all of the suspensions studied only when reliable in-house Au mass fractions and thorough mean particle size determinations were included in the calculation of the derived PNCs. The use of the particle size distribution over the mean size to derive PNCs resulted in larger differences for materials with a low contribution (<2%) of smaller NPs (30 nm), materials with a higher polydispersity (100 nm), or materials with two distinct subpopulations of particles (60 nm), regardless of NP coating.


Assuntos
Ouro , Nanopartículas Metálicas , Ouro/química , Espectrometria de Massas/métodos , Nanopartículas Metálicas/química , Tamanho da Partícula , Análise Espectral
4.
Anal Chim Acta ; 1175: 338671, 2021 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-34330435

RESUMO

Analytical techniques capable of determining the spatial distribution and quantity (mass and/or particle number) of engineered nanomaterials in organisms are essential for characterizing nano-bio interactions and for nanomaterial risk assessments. Here, we combine the use of dynamic secondary ion mass spectrometry (dynamic SIMS) and single particle inductively coupled mass spectrometry (spICP-MS) techniques to determine the biodistribution and quantity of gold nanoparticles (AuNPs) ingested by Caenorhabditis elegans. We report the application of SIMS in image depth profiling mode for visualizing, identifying, and characterizing the biodistribution of AuNPs ingested by nematodes in both the lateral and z (depth) dimensions. In parallel, conventional- and sp-ICP-MS quantified the mean number of AuNPs within the nematode, ranging from 2 to 36 NPs depending on the size of AuNP. The complementary data from both SIMS image depth profiling and spICP-MS provides a complete view of the uptake, translocation, and size distribution of ingested NPs within Caenorhabditis elegans.


Assuntos
Ouro , Nanopartículas Metálicas , Animais , Caenorhabditis elegans , Tamanho da Partícula , Espectrometria de Massa de Íon Secundário , Distribuição Tecidual
5.
Neurobiol Dis ; 130: 104524, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31276794

RESUMO

Tyrosine hydroxylase is the key enzyme controlling the synthesis of the catecholamines including dopamine. The breakdown of dopamine into toxic compounds has been suggested to have a key role in the degeneration of the dopaminergic neurons in Parkinson's disease. Humans are unique in containing four isoforms of tyrosine hydroxylase, but understanding of the role of these isoforms under normal conditions and in disease states is limited. The aim of this work was to determine the level and distribution of the four human isoforms in tissues from healthy controls and patients with Parkinson's disease. The results show that isoform 1 and isoform 2 are the major tyrosine hydroxylase isoforms in human brain, but that tyrosine hydroxylase isoform 2 is more abundant in the substantia nigra than the tyrosine hydroxylase isoform 1. The two minor isoforms, isoform 3 and isoform 4, are expressed at a proportionally higher level in the terminal field regions (caudate and putamen) compared to the substantia nigra. There was a selective loss of tyrosine hydroxylase isoform 1 in Parkinson's disease compared to age-matched controls and a corresponding increase in the proportion of tyrosine hydroxylase isoform 2. Phosphorylation of serine 40 was significantly increased in caudate, putamen and ventral tegmental area, but not in the substantia nigra, in Parkinson's disease brain. These results show a selective sparing of tyrosine hydroxylase isoform 2 in Parkinson's disease. Isoform 2 exhibits a reduced capacity for activation compared to isoform 1, which may account for the selective sparing of cells expressing isoform 2 in Parkinson's disease. Surviving neurons in Parkinson's disease brain exhibit a substantial increase in tyrosine hydroxylase phosphorylation consistent with a compensatory mechanism of increased dopamine synthesis in the terminal field regions.


Assuntos
Corpo Estriado/metabolismo , Doença de Parkinson/metabolismo , Isoformas de Proteínas/metabolismo , Substância Negra/metabolismo , Tirosina 3-Mono-Oxigenase/metabolismo , Neurônios Dopaminérgicos/metabolismo , Humanos , Fosforilação
6.
Anal Chem ; 90(24): 14376-14386, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30472826

RESUMO

Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique capable of simultaneously measuring nanoparticle size and number concentration of metal-containing nanoparticles (NPs) at environmental levels. single particle ICP-MS will become an established measurement method once the metrological quality of the measurement results it produces have been proven incontrovertibly. This Article presents the first validation of spICP-MS capabilities for measuring mean NP size and number size distribution of gold nanoparticles (AuNPs). The validation is achieved by (i) calibration based on the consensus value for particle size derived from six different sizing techniques applied to National Institute of Standards and Technology (NIST) Reference Material (RM) 8013; (ii) comparison with high-resolution scanning electron microscopy (HR-SEM) used as a reference method, which is linked to the International System of Units (SI) through a calibration standard characterized by the NIST metrological atomic force microscope; and (iii) evaluation of the uncertainty associated with the measurement of the mean particle size to enable comparison of the spICP-MS and HR-SEM methods. After establishing HR-SEM and spICP-MS measurement protocols, both methods were used to characterize commercial AuNP suspensions of three different sizes (30, 60, and 100 nm) with four different coatings and surface charge at pH 7. Single particle ICP-MS measurements (corroborated by HR-SEM) revealed the existence of two distinct subpopulations of particles in the number size distributions for four of the 60 nm commercial suspensions, a fact that was not apparent in the measurement results supplied by the vendor using transmission electron microscopy. This finding illustrates the utility of spICP-MS for routine characterization of commercial AuNP suspensions regardless of size or coating.

7.
Anal Bioanal Chem ; 410(4): 1265-1278, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29222652

RESUMO

A Standard Reference Material (SRM) of seaweed, SRM 3232 Kelp Powder (Thallus laminariae) has been developed to support food and dietary supplement measurements in compliance with the Food Safety Modernization Act (FSMA) and the Dietary Supplement Health and Education Act of 1994 (DSHEA). The material was characterized for nutritional minerals, arsenic species, isomers of vitamin K1, proximates, and toxic elements. Kelp is a rich source of vitamins and minerals, and it is an excellent source of dietary iodine. Kelp also contains a large amount of arsenic, which is toxic as inorganic species but much less so as organic species. To capture the dietary profile of kelp, certified values were issued for As, Ca, Cd, Cr, Cu, Fe, Hg, I, K, Mg, Mn, Mo, Na, Pb, and Zn. Reference values for proximates were assigned. For the first time, a certified value for iodine, reference values for isomers of vitamin K1, and reference values for arsenic species including arsenosugars were assigned in a seaweed. SRM 3232 fills a gap in Certified Reference Materials (CRMs) needed for quality assurance and method validation in the compositional measurements of kelp and similar seaweeds used as food and as dietary supplements. Graphical Absract Arsenic species and isomers of vitamin K1 were determined in the development of SRM 3232 Kelp Powder (Thallus laminariae).


Assuntos
Kelp/química , Pós , Cromatografia Líquida , Padrões de Referência , Espectrometria de Massas em Tandem
8.
Anal Bioanal Chem ; 409(25): 6027-6039, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28815280

RESUMO

Single particle ICP-MS has evolved rapidly as a quantitative method for determining nanoparticle size and number concentration at environmentally relevant exposure levels. Central to the application of spICP-MS is a commonly used, but not rigorously validated, calibration approach based on the measured transport efficiency and the response of ionic standards. In this work, we present a comprehensive and systematic study of the accuracy, precision and robustness of spICP-MS using the rigorously characterized reference material (RM) 8017 (Polyvinylpyrrolidone Coated Nominal 75 nm Silver Nanoparticles), recently issued by the National Institute of Standards and Technology (NIST). We report for the first time, statistically significant differences in frequency-based and size-based measures of transport efficiency with NIST RM 8013 Gold Nanoparticles and demonstrate that the size-based measure of transport efficiency is more robust and yields accurate results for the silver nanoparticle RM relative to TEM-based reference values. This finding is significant, because the frequency-based method is more widely applied. Furthermore, we demonstrate that the use of acidified ionic standards improves measurement of ICP-MS Ag response, but does not degrade the accuracy of the results for AgNP suspensions in water or various other diluents. Approaches for controlling AgNP dissolution were investigated and are shown to effectively improve particle stability in dilute suspensions required for spICP-MS analysis, while minimally affecting the measured intensity and allowing for more robust analysis. This study is an important and necessary advancement toward full validation and adoption of spICP-MS by the broader research community. Graphical abstract Measurement challenges in spICP-MS analysis.

9.
J Chromatogr A ; 1511: 59-67, 2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28697934

RESUMO

The physicochemical characterization of nanoparticles (NPs) is of paramount importance for tailoring and optimizing the properties of these materials as well as for evaluating the environmental fate and impact of the NPs. Characterizing the size and chemical identity of disperse NP sample populations can be accomplished by coupling size-based separation methods to physical and chemical detection methods. Informed decisions regarding the NPs can only be made, however, if the separations themselves are quantitative, i.e., if all or most of the analyte elutes from the column within the course of the experiment. We undertake here the size-exclusion chromatographic characterization of Au NPs spanning a six-fold range in mean size. The main problem which has plagued the size-exclusion chromatography (SEC) analysis of Au NPs, namely lack of quantitation accountability due to generally poor NP recovery from the columns, is overcome by carefully matching eluent formulation with the appropriate stationary phase chemistry, and by the use of on-line inductively coupled plasma mass spectrometry (ICP-MS) detection. Here, for the first time, we demonstrate the quantitative analysis of Au NPs by SEC/ICP-MS, including the analysis of a ternary NP blend. The SEC separations are contrasted to HDC/ICP-MS (HDC: hydrodynamic chromatography) separations employing the same stationary phase chemistry. Additionally, analysis of Au NPs by HDC with on-line quasi-elastic light scattering (QELS) allowed for continuous determination of NP size across the chromatographic profiles, circumventing issues related to the shedding of fines from the SEC columns. The use of chemically homogeneous reference materials with well-defined size range allowed for better assessment of the accuracy and precision of the analyses, and for a more direct interpretation of results, than would be possible employing less rigorously characterized analytes.


Assuntos
Cromatografia em Gel , Ouro/química , Nanopartículas Metálicas/análise , Difusão Dinâmica da Luz , Hidrodinâmica , Espectrometria de Massas , Nanopartículas Metálicas/química , Tamanho da Partícula
10.
Front Chem ; 5: 6, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28271059

RESUMO

Silver nanoparticles (AgNPs) show different physical and chemical properties compared to their macroscale analogs. This is primarily due to their small size and, consequently, the exceptional surface area of these materials. Presently, advances in the synthesis, stabilization, and production of AgNPs have fostered a new generation of commercial products and intensified scientific investigation within the nanotechnology field. The use of AgNPs in commercial products is increasing and impacts on the environment and human health are largely unknown. This article discusses advances in AgNP production and presents an overview of the commercial, societal, and environmental impacts of this emerging nanoparticle (NP), and nanomaterials in general. Finally, we examine the challenges associated with AgNP characterization, discuss the importance of the development of NP reference materials (RMs) and explore their role as a metrological mechanism to improve the quality and comparability of NP measurements.

12.
ACS Nano ; 11(1): 526-540, 2017 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-27983787

RESUMO

For environmental studies assessing uptake of orally ingested engineered nanoparticles (ENPs), a key step in ensuring accurate quantification of ingested ENPs is efficient separation of the organism from ENPs that are either nonspecifically adsorbed to the organism and/or suspended in the dispersion following exposure. Here, we measure the uptake of 30 and 60 nm gold nanoparticles (AuNPs) by the nematode, Caenorhabditis elegans, using a sucrose density gradient centrifugation protocol to remove noningested AuNPs. Both conventional inductively coupled plasma mass spectrometry (ICP-MS) and single particle (sp)ICP-MS are utilized to measure the total mass and size distribution, respectively, of ingested AuNPs. Scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS) imaging confirmed that traditional nematode washing procedures were ineffective at removing excess suspended and/or adsorbed AuNPs after exposure. Water rinsing procedures had AuNP removal efficiencies ranging from 57 to 97% and 22 to 83%, while the sucrose density gradient procedure had removal efficiencies of 100 and 93 to 98%, respectively, for the 30 and 60 nm AuNP exposure conditions. Quantification of total Au uptake was performed following acidic digestion of nonexposed and Au-exposed nematodes, whereas an alkaline digestion procedure was optimized for the liberation of ingested AuNPs for spICP-MS characterization. Size distributions and particle number concentrations were determined for AuNPs ingested by nematodes with corresponding confirmation of nematode uptake via high-pressure freezing/freeze substitution resin preparation and large-area SEM imaging. Methods for the separation and in vivo quantification of ENPs in multicellular organisms will facilitate robust studies of ENP uptake, biotransformation, and hazard assessment in the environment.


Assuntos
Caenorhabditis elegans/química , Ouro/isolamento & purificação , Nanopartículas Metálicas/química , Imagem Óptica , Animais , Centrifugação com Gradiente de Concentração , Ouro/química , Espectrometria de Massas , Tamanho da Partícula , Sacarose/química , Propriedades de Superfície
13.
Anal Bioanal Chem ; 408(16): 4257-66, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27074778

RESUMO

Two new Standard Reference Materials (SRMs), SRM 2786 Fine Particulate Matter (<4 µm) and SRM 2787 Fine Particulate Matter (<10 µm) have been developed in support of the US Environmental Protection Agency's National Ambient Air Quality Standards for particulate matter (PM). These materials have been characterized for the mass fractions of selected polycyclic aromatic hydrocarbons (PAHs), nitrated PAHs, brominated diphenyl ether (BDE) congeners, hexabromocyclododecane (HBCD) isomers, sugars, polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners, and inorganic constituents, as well as particle-size characteristics. These materials are the first Certified Reference Materials available to support measurements of both organic and inorganic constituents in fine PM. In addition, values for PAHs are available for RM 8785 Air Particulate Matter on Filter Media. As such, these SRMs will be useful as quality control samples for ensuring compatibility of results among PM monitoring studies and will fill a void to assess the accuracy of analytical methods used in these studies. Graphical Abstract Removal of PM from filter for the preparation of SRM 2786 Fine Particulate Matter.

14.
Mov Disord ; 30(12): 1639-47, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25594542

RESUMO

Lysosomes are the primary catabolic compartment for the degradation of intracellular proteins through autophagy. The presence of abnormal intracellular α-synuclein-positive aggregates in Parkinson's disease (PD) indicates that the degradative capacity of lysosomes is impaired in PD. Specific dysfunction of chaperone-mediated autophagy (CMA) in PD is suggested by reductions in the CMA membrane receptor, lysosomal-associated membrane protein (LAMP) 2A, although whether LAMP2A is the only LAMP2 isoform affected by PD is unknown. Messenger RNA (mRNA) and protein expression of all three LAMP2 isoforms was assessed in brain extracts from regions with and without PD-related increases in α-synuclein in autopsy samples from subjects in the early pathological stage of PD (n = 9), compared to age- and postmortem delay-matched controls (n = 10). In the early stages of PD, mRNA expression of all LAMP2 isoforms was not different from controls, with LAMP2B and LAMP2C protein levels also unchanged in PD. The selective loss of LAMP2A protein directly correlated with the increased levels of α-synuclein and decreased levels of the CMA chaperone heat shock cognate protein 70 in the same PD samples, as well as with the accumulation of cytosolic CMA substrate proteins. Our data show that LAMP2 protein isoforms are differentially affected in the early stages of PD, with LAMP2A selectively reduced in association with increased α-synuclein, and suggests that dysregulation of CMA-mediated protein degradation occurs before substantial α-synuclein aggregation in PD.


Assuntos
Proteína 2 de Membrana Associada ao Lisossomo/metabolismo , Doença de Parkinson/metabolismo , Doença de Parkinson/patologia , Isoformas de Proteínas/metabolismo , Idoso , Idoso de 80 Anos ou mais , Encéfalo/metabolismo , Colesterol/metabolismo , Feminino , Proteínas de Choque Térmico HSP70/genética , Proteínas de Choque Térmico HSP70/metabolismo , Humanos , Metabolismo dos Lipídeos , Proteína 2 de Membrana Associada ao Lisossomo/genética , Masculino , Pessoa de Meia-Idade , Isoformas de Proteínas/genética , RNA Mensageiro/metabolismo , Estatísticas não Paramétricas , alfa-Sinucleína/genética , alfa-Sinucleína/metabolismo
16.
Autophagy ; 10(7): 1350-1, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24915553

RESUMO

Parkinson disease (PD) is a progressive neurodegenerative movement disorder characterized pathologically by abnormal SNCA/α-synuclein protein inclusions in neurons. Impaired lysosomal autophagic degradation of cellular proteins is implicated in PD pathogenesis and progression. Heterozygous GBA mutations, encoding lysosomal GBA/glucocerebrosidase (glucosidase, ß, acid), are the greatest genetic risk factor for PD, and reduced GBA and SNCA accumulation are related in PD models. Here we review our recent human brain tissue study demonstrating that GBA deficits in sporadic PD are related to the early accumulation of SNCA, and dysregulation of chaperone-mediated autophagy (CMA) pathways and lipid metabolism.


Assuntos
Glucosilceramidase/deficiência , Doença de Parkinson/enzimologia , Doença de Parkinson/patologia , Autofagia , Humanos , Metabolismo dos Lipídeos , Chaperonas Moleculares/metabolismo , alfa-Sinucleína/metabolismo
17.
Mov Disord ; 29(4): 518-26, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24822250

RESUMO

Genetic studies have provided increasing evidence that ceramide homeostasis plays a role in neurodegenerative diseases including Parkinson's disease (PD). It is known that the relative amounts of different ceramide molecular species, as defined by their fatty acyl chain length, regulate ceramide function in lipid membranes and in signaling pathways. In the present study we used a comprehensive sphingolipidomic case-control approach to determine the effects of PD on ceramide composition in postmortem brain tissue from the anterior cingulate cortex (a region with significant PD pathology) and the occipital cortex (spared in PD), also assessing mRNA expression of the major ceramide synthase genes that regulate ceramide acyl chain composition in the same tissue using quantitative PCR. In PD anterior cingulate cortex but not occipital cortex, total ceramide and sphingomyelin levels were reduced from control levels by 53% (P < 0.001) and 42% (P < 0.001), respectively. Of the 13 ceramide and 15 sphingomyelin molecular lipid species identified and quantified, there was a significant shift in the ceramide acyl chain composition toward shorter acyl chain length in the PD anterior cingulate cortex. This PD-associated change in ceramide acyl chain composition was accompanied by an upregulation of ceramide synthase-1 gene expression, which we consider may represent a response to reduced ceramide levels. These data suggest a significant shift in ceramide function in lipid membranes and signaling pathways occurs in regions with PD pathology. Identifying the regulatory mechanisms precipitating this change may provide novel targets for future therapeutics.


Assuntos
Encéfalo/metabolismo , Ceramidas/metabolismo , Expressão Gênica , Oxirredutases/genética , Doença de Parkinson/genética , Idoso , Idoso de 80 Anos ou mais , Encéfalo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/metabolismo , Doença de Parkinson/patologia
18.
Anal Chem ; 86(7): 3405-14, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24575780

RESUMO

The increasing application of engineered nanomaterials (ENMs) in consumer and medical products has motivated the development of single-particle inductively coupled plasma mass spectrometry (spICP-MS) for characterizing nanoparticles under realistic environmental exposure conditions. Recent studies have established a set of metrological criteria and evaluated the feasibility of spICP-MS for sizing or quantifying various highly commercialized ENMs. However, less is known about the performance of spICP-MS for detecting nanoparticles with sizes greater than 80 nm. This paper presents a systematic study on spICP-MS for accurate size measurement of gold nanoparticles from 10 to 200 nm. We show that dwell time contributes significantly to the quality of data, with the optimal dwell time that limits split particle events, particle coincidences and false positives being 10 ms. A simple approach to correct for split particle events is demonstrated. We show that transient features of single particle events can be temporally resolved on a conventional quadrupole ICP-MS system using a sufficiently short dwell time (0.1 ms). We propose an intensity-size diagram for estimating the linear dynamic size range and guiding the selection of ICP-MS operating conditions. The linear dynamic size range of the ICP-MS system under standard (highest) sensitivity conditions is 10 to 70 nm but can be further extended to 200 nm by operating in less sensitive modes. Finally, the ability of spICP-MS to characterize heterogeneous forms of metal containing nanoparticles is evaluated in mixtures containing both dissolved and poly disperse nanoparticulate Au.


Assuntos
Ouro/química , Nanopartículas Metálicas , Espectrometria de Massas , Tamanho da Partícula
19.
Brain ; 137(Pt 3): 834-48, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24477431

RESUMO

Heterozygous mutations in GBA1, the gene encoding lysosomal glucocerebrosidase, are the most frequent known genetic risk factor for Parkinson's disease. Reduced glucocerebrosidase and α-synuclein accumulation are directly related in cell models of Parkinson's disease. We investigated relationships between Parkinson's disease-specific glucocerebrosidase deficits, glucocerebrosidase-related pathways, and α-synuclein levels in brain tissue from subjects with sporadic Parkinson's disease without GBA1 mutations. Brain regions with and without a Parkinson's disease-related increase in α-synuclein levels were assessed in autopsy samples from subjects with sporadic Parkinson's disease (n = 19) and age- and post-mortem delay-matched controls (n = 10). Levels of glucocerebrosidase, α-synuclein and related lysosomal and autophagic proteins were assessed by western blotting. Glucocerebrosidase enzyme activity was measured using a fluorimetric assay, and glucocerebrosidase and α-synuclein messenger RNA expression determined by quantitative polymerase chain reaction. Related sphingolipids were analysed by mass spectrometry. Multivariate statistical analyses were performed to identify differences between disease groups and regions, with non-parametric correlations used to identify relationships between variables. Glucocerebrosidase protein levels and enzyme activity were selectively reduced in the early stages of Parkinson's disease in regions with increased α-synuclein levels although limited inclusion formation, whereas GBA1 messenger RNA expression was non-selectively reduced in Parkinson's disease. The selective loss of lysosomal glucocerebrosidase was directly related to reduced lysosomal chaperone-mediated autophagy, increased α-synuclein and decreased ceramide. Glucocerebrosidase deficits in sporadic Parkinson's disease are related to the abnormal accumulation of α-synuclein and are associated with substantial alterations in lysosomal chaperone-mediated autophagy pathways and lipid metabolism. Our data suggest that the early selective Parkinson's disease changes are likely a result of the redistribution of cellular membrane proteins leading to a chronic reduction in lysosome function in brain regions vulnerable to Parkinson's disease pathology.


Assuntos
Glucosilceramidase/antagonistas & inibidores , Doença de Parkinson/metabolismo , Regulação para Cima/fisiologia , alfa-Sinucleína/biossíntese , Idoso , Idoso de 80 Anos ou mais , Autofagia/fisiologia , Encéfalo/enzimologia , Encéfalo/metabolismo , Encéfalo/patologia , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Glucosilceramidase/genética , Glucosilceramidase/metabolismo , Humanos , Lisossomos/enzimologia , Masculino , Chaperonas Moleculares/fisiologia , Mutação/genética , Doença de Parkinson/enzimologia , Doença de Parkinson/patologia , alfa-Sinucleína/metabolismo
20.
J Radioanal Nucl Chem ; 299(3): 1555-1563, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26300575

RESUMO

A newly developed procedure for determination of arsenic by radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in SRM 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1×1014cm-2s-1. After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix by extraction into zinc diethyldithiocarbamate in chloroform, and 76As quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma - mass spectrometry (ICP-MS) values from NIST and collaborating laboratories to provide certified values of (10.81 ± 0.54) µg/kg and (213.1 ± 0.73) µg/kg for SRM 2668 Levels I and II, and certified values of (21.66 ± 0.73) µg/kg, (52.7 ± 1.1) µg/kg, and (78.8 ± 4.9) µg/kg for SRM 955c Levels 2, 3, and 4 respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level 1, an information value of < 5 µg/kg was assigned for this material.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA